Every business is trying to conserve energy in the face of high utility costs, so getting the best return on investment (ROI) is critical for maintaining a healthy balance sheet. The decision to replace existing motors with newer premium efficiency motors needs to take into account both the increased energy efficiency as well as ROI gained by installing a new motor.

Background on Classes of Motor Efficiency

There are three basic standards of motor efficiency: pre-EPAct, EPAct, and Premium Efficiency (also known as NEMA Premium). In 1992, the Department of Energy issued the Environmental Policy Act of 1992 (EPAct ’92). This legislation set minimum standards for efficiency of the majority of general purpose motors sold in the U.S. The actual requirements for motors went into effect in 1997. Motors sold after EPAct ’92 went into effect are commonly referred to as EPAct motors.

In 2007, the Energy Independence and Security Act of 2007 (EISA) was signed into law. This legislation raised the minimum efficiency for most induction motors sold in the U.S even higher. The requirements for this law went into effect in 2010. Motors that meet the latest efficiency guidelines are referred to as Premium Efficiency (PE) or NEMA Premium motors.

Since 2010, the United States Department of Energy has been issuing new rules mandating increased energy efficiency requirements for motors originally excluded from EISA 2007. The new rules enforce efficiency standards for small motors, open drip-proof motors, and other categories not covered in EISA 2007’s Premium Efficiency mandates. To learn more about the new rules visit: https://federalregister.gov/a/2014-11201

Rewind or Replace?

One of the first decisions made when a motor fails is whether to rewind or replace the motor. The biggest determining factors in that decision are the age of the motor, the type of motor involved, availability, how often the motor runs, and its efficiency. When a pre-EPAct motor isn’t working properly, replacement is most always preferred (age of the motor and gains in efficiency play a significant role in the ROI).

When an EPAct motor fails, the increased savings of replacing this motor with a Premium Efficiency motor requires consideration. If a Premium Efficiency motor fails, the repair/replace decision becomes even less clear-cut. The Department of Energy has information that can help you determine the payback when deciding on purchasing a new Premium Efficiency motor vs. repairing pre-Epact, EPAct, or existing Premium Efficient motors. http://1.usa.gov/MS3AbN

In the past, rewinding a motor usually meant losing efficiency, but that’s no longer true, as original motor efficiency can be maintained in most cases. In fact, it’s sometimes possible to increase efficiency with a motor rewind. To determine the effect on efficiency for a specific motor, experts at a motor repair shop should be consulted.

When the motor in question is a special or custom motor, additional factors help determine whether to repair or replace, such as the longer lead times required for custom motors, and the higher costs of replacing them.

In these cases, rewinding may be a more attractive proposition. For non-custom standard efficiency motors, replacement is often the better way to go because the efficiency gains usually outweigh the cost of a new motor.

The amount of time a motor runs can also help determine whether rewinding or replacing is the better option. For motors that operate continually, the ROI for a new, premium efficiency motor can be achieved fairly quickly. For motors that only run periodically, careful analysis is needed in the cost calculations for replacing versus rewinding. To help with these calculations there are several Web sites, such as the Department of Energy website. The Department of Energy also provides a free software package, MotorMaster+, which assists with motor rewind/replace decisions, as well as creating a motor survey if replacing is determined to be the better option.

Considerations for Replacing a Motor

A common mistake that happens when the decision is made to replace a motor is thinking that buying any new premium efficiency motor will deliver optimal efficiency. When trying to boost savings by increasing energy efficiency, selecting the right-sized motor is at least as important as the energy efficiency of the new motor.

If the new motor is oversized, the energy savings will be less than if the right sized motor was installed. The best method for determining the right size motor is to conduct a thorough motor survey. Correctly sizing an AC motor is important because overloaded motors can overheat, and underloaded motors waste energy. A motor’s energy usage accounts for more than 95 percent of its lifetime cost, so achieving maximum energy efficiency is crucial, and rightsizing the motor is a key step.

AC_Motors_2.JPG

Sizing and Output Speed

The two most important factors when sizing any type of load are required torque and speed. Finding the required output speed is usually easily accomplished by determining the design specifications. However, it’s usually more difficult to determine the correct torque.

A too-frequent problem in today’s industrial applications is the use of oversized motors, an issue that can be addressed with more precise up-front engineering. For example, if an application really requires slightly more than 5 horsepower (hp) at infrequent intervals, a 7.5 hp motor is often installed to make sure there’s enough headroom. In this situation, the 7.5 hp motor will definitely work, but it will be running well below full load torque and further down the efficiency curve (wasting energy).

For applications that only require the motor to operate above full load for short periods of time, selecting the right size motor with a higher service factor could be a better option. For example, if a motor has a 1.15 service factor, it can occasionally handle an additional 15 percent load without damaging the motor.

The Importance of a Motor Survey

Conducting a motor survey is the best way to correctly size a replacement motor. A motor survey should begin by reviewing and cataloging the nameplate information on the current motor to obtain the rated speed, efficiency, full-load current, etc.

The motor nameplate is the first step of a motor survey. It supplies available information, such as speed and full-load current, to help select the right size motor.

AC_Motors_3.JPG

The next step is to use a clamp-on meter to monitor the current the motor is drawing during normal operation. Most systems have many unknown factors, such as friction and mechanical transmission efficiencies, which affect motor loading. Thus, getting an actual measurement of the current going into the motor helps determine the true required motor size.

Motors operate most efficiently near full load, so determining load requirements accurately is important. The greatest efficiency is achieved above 70 percent of full load torque. Below 50 – 60 percent, efficiencies start to drop off dramatically.

There are several web sites that provide information on how to determine motor load size, such as http://1.usa.gov/LDOEbW.

Conducting a thorough motor study may seem like a complicated task, but there are tools available to help with the calculations.

Moreover, investing the time to conduct a thorough motor survey will help ensure the correct size motor, one that will deliver maximum savings throughout the motor’s life.

A wealth of additional information (motor survey forms, case studies, software tools, and fact sheets) can be found at the Department of Energy’s Web site.

AutomationDirect_Link_Logo.JPG

AC_Motors_4.JPG

 

 

 


Editor's Pick: Featured Article


DCS Put to the Ultimate Test Part 1 Torsion Tests by HELUKABEL 1 400x275

Cables and wires in industrial robots and other moving machine parts are often required to withstand extreme stresses caused by torsion. Constant repetitive movements put materials under considerable strain. At the same time, operators expect components to function perfectly and reliably throughout their entire service life to avoid disruptions, outages and safety hazards.

For this reason, at HELUKABEL, we simulate intensive and continuous torsion stresses under realistic conditions with our high-tech testing equipment in Windsbach. We have several types of apparatus for doing this because some of our customers, for example those in the automotive industry, have very precise specifications for how a torsion test is carried out. The tests show that our cables and wires withstand speeds up to 1,000°/s, accelerations up to 2,000°/s² and torsion angles up to 720°. Hence, we make sure that each product always meets our customers’ high standards, and that they receive the impeccable quality they rightly expect from us as a leading supplier of cables, wires and accessories for more than 40 years.

What Is Torsion?

 

To learn the answer, click here 

 


Sponsored Content


30 Minute Live Webinar 2:30 PM ET January 19th, 2023

DCS Siemens Sponsored Content 30 Minute Live Webinar January19 2023 300x250

 

 

With PC-based automation, you can implement applications and solutions that far exceed the functions of a classic controller. SIMATIC PC-based products offer you a flexible, innovative platform with long-term availability that give you a home field advantage when meeting the challenges of the digital factory for your machines and plants.

  

Register now

 


 


DCS Festo Didactic at the Forefront of Developing Canadas Future Workforce 1 400x275

With Canadian manufacturing suffering from a growing labour shortage, the participation of industry in skills development is emerging as a vital component in hiring and retention.

The needs are stark: The Canadian Exporters and Manufacturers Association says almost 40% of its members have jobs they can’t fill. Five years from now, 60% expect to be short-staffed, especially when it comes to skilled trades. Statistics Canada forecasts the country’s labour force growth rate will remain below 0.2% for the rest of the decade, below replacement levels.

This growing shortage is affecting companies of all sizes. Already, some manufacturers acknowledge losing out on contracts because they can’t find the manpower to fulfill them.

In reality, the challenge is two-fold: to replenish and expand the workforce to help close the gap between the number of job seekers and vacancies through 2030 when the last baby boomers reach age 65, and ensure workers get opportunities throughout their careers to upgrade or add to their skillset as current technologies evolve and new ones emerge. Festo, through Festo Didactic, one of the world leading provider of equipment and solutions for technical education, intends to help Canada meet this challenge on both fronts. In essence, the approach Festo has always taken is that the learning never stops.

 

Read more here


 

Product News

  • Prev
  When working with industrial pumping, such as crop irrigation or wastewater ...
  Littelfuse, Inc. has announced the new C&K Switches NanoT product line, a series ...
  VFD cables are a critical component to extend a motor’s life cycle within a VFD ...
  AutomationDirect has added new models of Dold safety relays to their line of safety ...
  AutomationDirect has added more low-cost ProSense float level switches. The new ...
  AutomationDirect has added new cable entry system options to their Murrplastik ...
   Emerson recently introduced the ASCO™ Series 209 proportional flow control ...
  Omron Automation Americas will introduce two new AOI systems at IPC Apex 2023 in San ...
  Teledyne FLIR Integrated Imaging Solutions is pleased to announce the all new ...
  ABB’s Sensi+ analyzer offers a reliable new solution which simplifies and reduces the ...

New Product

DCS New Emerson Valves Deliver Proportional Flow Control Performance 1 400x275

Emerson recently introduced the ASCO™ Series 209 proportional flow control valves, which offer the highest standards of precision, pressure ratings, flow characteristics and energy efficiency available in a purpose-built, compact architecture. With this combination of size and performance, Series 209 valves allow users to precisely regulate the flow of fluid in a wide range of devices that require exacting performance, like those found in the medical equipment, food and beverage, and heating, ventilation and air conditioning (HVAC) industries. 

Accuracy, response time and repeatability are critical in high-precision flow control applications, such as controlling tool speed in dental chairs, the flow of steam in coffee makers, water flow in cooling systems and hydrogen flow in fuel cells. Series 209 valves have low hysteresis (less than or equal to 5%), excellent repeatability (less than or equal to 1%) and high sensitivity (less than or equal to 0.2%) that contribute to their precision. 


To find out more, click here


 


Featured Product

DCS Teledyne Announces New Ladybug6 Cameras for High Accuracy 1 400x275 

Teledyne FLIR Integrated Imaging Solutions is pleased to announce the all new Ladybug6— the latest addition to its field proven Ladybug series. Ladybug6 is the leading high-resolution camera designed to capture 360-degree spherical images from moving platforms in all-weather conditions. Its industrial grade design and out-of-the-box factory calibration produces 72 Megapixel (MP) images with pixel values that are spatially accurate within +/- 2 mm at 10-meter distance.

“The new Teledyne Ladybug6 is designed for mobile mapping and all-weather inspection projects requiring excellent image quality and high resolution,” said Mike Lee, Senior Product Manager at Teledyne FLIR. “With the addition of Ladybug6, we are now pleased to offer a wider variety of spherical cameras with higher resolutions ranging from 30 MP to 72 MP.”

 

To learn more, click here


 

Latest News

  • Prev
  The Ontario government has concluded a successful trade mission to South Korea and ...
  ABB and Hydrogen Optimized Inc. (HOI), the Canadian technology innovator unlocking ...
  World leaders from government and industry will meet in the southern Denmark city of ...
  The ABB #BuildtheFuture Roadshow delivers the latest electrical products, services, ...
  Global industry is accelerating its investment in energy efficiency in the next five ...
  In March 2022, the new edition of the installation standard IEC 61918:2018/AMD1:2022 ...
  On this episode of the Allied Expert Advice podcast, Carlos Riano, Senior Offer ...
  Advanced Micro Controls Inc. (AMCI) has realized growth throughout the Midwest United ...
  Ballard Power Systems recently announced that the company has launched a three-year ...
  Discover the difference a Gutor-backed setup can have on your business and ...

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2025 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil